Increasing compressor pressure can seem like a quick solution when machinery is struggling. But setting the system higher than necessary often increases electricity consumption, makes leaks more expensive and places additional demands on equipment. The better approach is to establish the pressure each process actually needs, then investigate why that pressure is not reaching it.

Why higher pressure costs more

For a typical industrial compressed air system, a commonly used rule of thumb is that increasing discharge pressure by 1 bar can raise compressor energy consumption by approximately 6–8%. The actual change depends on compressor type, controls and operating conditions; it should not be treated as a guaranteed saving for every installation.

Higher system pressure also increases the flow through many leaks and unregulated uses of compressed air. This means the cost can be greater than the additional compressor power alone.

Compressor pressure is not the same as pressure at the machine

A compressor may show 8 bar while a production machine receives considerably less during peak demand. The difference can come from restrictions and pressure losses across the system, including:

  • Undersized or excessively long pipework and flexible hoses
  • Blocked or incorrectly sized filters
  • Restrictive couplings, valves and regulators
  • Leaks and simultaneous demand from other equipment
  • Insufficient local storage for short, high-flow demands

Raising compressor pressure can mask these issues without fixing them.

Measure pressure while equipment is operating

Static pressure readings rarely tell the whole story. Record pressure at the compressor outlet, downstream of treatment equipment and at critical points of use while the plant is running normally and during its highest-demand cycles.

For intermittent processes, pressure logging can reveal short drops that a standard gauge may miss. Combine these measurements with compressor load, energy and air-demand information where appropriate.

Find the lowest reliable operating pressure

Start with the machinery manufacturer’s minimum inlet-pressure requirement, allowing for realistic pressure losses and suitable control margins. Correct restrictions, leaks and poor distribution before changing the compressor’s setpoint. Any reduction should be made carefully and checked during maximum production demand, not just during quiet periods.

Where several machines require different pressures, local regulation or a separate supply arrangement may be more efficient than operating the entire factory at the highest required pressure.

What about variable-speed compressors?

A variable-speed compressor can adjust output to changing demand, but it does not eliminate the energy penalty of unnecessarily high pressure. Correct sizing, pressure settings and system design remain important for both fixed-speed and variable-speed equipment.

When should you investigate?

If operators routinely increase pressure to keep production running, if pressure falls sharply when a machine starts, or if the compressor runs heavily outside production hours, the system deserves a closer look.

Get practical advice on your compressed air system

West Midlands Compressors Ltd supports industrial businesses with compressor servicing, pressure-drop investigations, pipework improvements and compressed air performance assessments across the West Midlands and surrounding counties. Contact our team to discuss your installation and identify the right checks before investing in additional compressor capacity.